3M FERRITE TILED SHIELDED SEMI - ANECHOIC CHAMBER:

Features:

  • E-field Shielding better than 100 dB from 30 MHz.

Applications: 

  • Radiated emission and susceptibility of electrical or electronics product can be measured upto 6GHz.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

 

RADIATED EMISSION MEASUREMENT FACILITY:

Service Name:

  • Measurement of Radiated emission from electrical or electronic product as per CISPR 11, 32 & FCC part 15 standards.

Features:

  • Measurement distance can be set 3mtr and Rx antenna height can be varied from 1 to 4mtr. 360º azimuth rotation of the EUT can be given.

Applications:

  • Electrical or electronics product with input current less than 20A.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Facility is FCC listed. Radiated emission can be measured from 30MHz to 6 GHz.

 

RADIATED SUSCEPTIBILITY TEST FACILITY:

Service name:

  • Radiated susceptibility test of electrical or electronic product as per IEC 61000-4-3 standard.

Features:

  • Measurement distance can be set 3mtr and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points.

Applications:

  • Electrical or electronics product with input current less than 20A.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Radiated Susceptibility can be test from 80MHz to 6 GHz

 

MAGNETIC FIELD IMMUNITY TEST FACILITY:

Service Name:

  • Magnetic field Immunity test of electrical or electronic product as per IEC 61000-4-8 standard.

Features:

  • Field Immunity can be tested at 50Hz. Severity level can be upto 300 A/m for continuous and upto 1000 A/m for short duration.

Applications:

  • Electronics product with CRT display with input current less than 20A.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Immunity can be tested at power line frequency and field strength upto 5 Gauss.

 

CONDUCTED EMISSION MEASUREMENT FACILITY:

Service Name:

  • Measurement of conducted emission from electrical or electronic product as per CISPR 11, 32 & FCC part 15 standards.

Features:

  • Conducted emission measurement of 3 phase EUT is possible and input current upto 25A.

Applications:

  • Electrical or electronics product.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Conducted Emission can be measured from 150KHz to 30MHz and also as per FCC standard.

 

ELECTRO STATIC DISCHARGE TEST FACILITY:

Service name:

  • ESD test of electrical or electronic product as per IEC 61000-4-2 standard.

Features:

  • The severity level for air discharge is upto ±15 KV and contact discharge is upto ±8 KV. Pulse rise time is between 0.7nS to 1nS.

Applications:

  • Electronic equipment sensitive to static discharge.

Users:

  • Railway vendors and other Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • ESD test of EUT can be carried out upto ±15 KV (air discharge).

 

ELECTRICAL FAST TRANSIENT / BURST TEST FACILITY:

Service name:

  • EFT/Burst test of electrical or electronic product as per IEC 61000-4-4 standard.

Features:

  • Pulse Rise time is 5 nS, Pulse width is 50 nS, Burst duration is 15 mS, Burst Period is 300 mS and Test voltage upto ± 4 KV

Applications:

  • Electrical or electronic equipment with input current less than 16A.

Users:

  • Railway vendors and other Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • EFT/Burst of EUT can be carried out upto ±4 KV and upto 5 KHz repetition rate.

 

HIGH ENERGY SURGE IMMUNITY TEST FACILITY:

Service Name: 

  • High energy surge immunity test of electrical or electronic product as per IEC 61000-4-5 standard.

Features: 

  • Pulse Rise time is 1.2 µS, Pulse width is 50 µS and Test voltage upto ± 4 KV.

Applications: 

  • Electrical or electronic equipment with input current less than 16A.

Users: 

  • Railway vendors and other Industries in and around Kolkata and Eastern India.

Location of facility: 

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail: 

  • Surge generator can deliver 1.2/50µS voltage surge across high load resistance and 8/20µS current surge into a short circuit.

 

SLOW DAMP OSCILLATORY TEST  FACILITY:

Service Name:

  • Measurement of slow damp oscillatory test of electrical or electronic product as per IEC 61000-4-18 standard.

Features:

  • Voltage Rise time is 75 nS, voltage oscillation frequency 100kHz and 1MHz.

Applications:

  • Electrical or electronic equipment with input current less than 16A.

Users:

  • Railway vendors and other Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Slow damp oscillatory wave of EUT can be carried out upto ±1KV (line-line) and  ±2KV (line-ground).

 

VOLTAGE DIPS, SHORT INTERRUPTION AND VOLTAGE VARIATION IMMUNITY TEST FACILITY:

Service Name:

  • Measurement of Voltage dips, short interruption and voltage variation immunity test of electrical or electronic product as per IEC 61000-4-11 standard.

Features:

  • Voltage dips short interruption 0%, 40%, 70% & and 80%.

Applications:

  • Electrical or electronic equipment with input current less than 16A.

Users:

  • Railway vendors and other Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Voltage dips short interruption 0%, 40%, 70% & and 80%.

 

CONDUCTED SUSCEPTIBILITY TEST FACILITY:

Service Name:

  • Conducted susceptibility test of electrical or electronic product as per IEC 61000-4-6 standard.

Features:

  • The 10VRMS can be created on the EUT.

Applications:

  • Electrical or electronics product with input current less than 20A.

Users:

  • Industries in and around Kolkata and Eastern India.

Location of facility:

  • SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Other Detail:

  • Conducted Susceptibility can be test from 150kHz to 80MHz.

 

 

  • Tariff chart for EMI/EMC Tests & Measurements  - NEW        

Click here for details


Note :  Charges for consultancy services is considered on case to case basis

TWEETS @SAMEER_RnD

What's New

Microwave and millimeterwave measurements:

  • Vector Network Analyzer
  • Scalar Network Analyzer
  • Spectrum Analyzer
  • Power Meter
  • Phase Noise & Noise figure
  • Signal Generator
  • Antenna Measurement Instrumentation

Mechanical CAD

  • Auto CAD
  • Inventer
  • ProE