- E-field Shielding better than 100 dB from 30 MHz.
- Radiated emission and susceptibility of electrical or electronics product can be measured upto 1 GHz.
- Industries in and around Kolkata and Eastern India.
- SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.

Service name :
Applications :
- Measurement of Radiated emission from electrical or electronic product as per CISPR 11,22 FCC part 15 standard.
- Measurement distance can be set 3M and Rx antenna height can be varied from 1M to 4M. 360º azimuth rotation of the EUT can be given.
- Electrical or electronics product with input current less than 20A.
- Industries in and around Kolkata and Eastern India.
- SAMEER Kolkata Centre, Sector V, Salt Lake Electronics Complex.
- Facility is FCC listed. Radiated emission can be measured from 30MHz to 1 GHz

Service name :
- Radiated susceptibility test of electrical or electronic product as per IEC 61000-4-3 standard.
- Measurement distance can be set 3M and Field upto 10 V/M can be created on the EUT. Field uniformity better than 6dB for 75% or more test points.